Welcome to Würth India For trade customers only

Drop-in anchor W-ED/S

Wedge anchor W-ED/S steel zinc plated
ANC-(W-ED/S)-(A2K)-M10

Art.-no. 090401010
EAN 4053479311043

Prices for customers after login
Drop-in anchor W-ED/S

Art.-no. 090401010

Prices for customers after login
Quantity
PU
x 1 pcs

Exclusively for trade customers

Register now and access more than 125,000 products

Female thread anchor with metric thread for economical anchoring in concrete, zinc-plated steel
  • Small drill hole depth

  • High load-bearing capacities

  • Visual setting check and hand protection when installing with the marking/expander tool

  • Mechanical setting tool makes installation quicker and easier

  • Immediate load-bearing capacity – no waiting

  • Attached part can easily be removed at any time

  • The attached part can be anchored with a fastening screw or a threaded rod

  • No installation torque required

  • The stop bit used with the attachable expander tool makes it quicker and easier to install. The matching drill holes make the installation even more secure.
Proof of Performance
  • ETA-02/0044 for individual fixing point, option 7, uncracked concrete

  • ETA-05/0120 for anchors in a redundant non-structural system, uncracked and cracked concrete, M6-M16

  • Fire resistance: F30, F60, F90 and F120; exposure to fire according to DIN 4102-2:1977-09 (UTTC - uniform temperature time curve)

  • Fire resistance: R30, R60, R90 and R120; TR020 (included in ETA-05/0120)
Notice

Drive-in anchor W-ED/A4 see [13.2]


Drive-in anchor W-ED, M12 (for core drills), and W-ED, DW15, see [13.3]

Application area
Suspended ceilings

Drill the hole

Clean the drill hole

Knock in anchor until flush

Anchor with expander tool

Fit component, apply torque

  • ETA-02/0044 for individual fixing point, option 7, uncracked concrete

  • ETA-05/0120 for anchors in a redundant non-structural system, uncracked and cracked concrete, M6-M16

  • Fire resistance: F30, F60, F90 and F120; exposure to fire according to DIN 4102-2:1977-09 (UTTC - uniform temperature time curve)

  • Fire resistance: R30, R60, R90 and R120; TR020 (included in ETA-05/0120)
Product information

Datasheets(X)

CAD data (available after login)

Certificates/ Documents

 | 

 | 

Application area

Individual fixing point: Normal weight concrete C20/25 to C50/60 (uncracked concrete)



Anchors in a redundant non-structural system: Anchorage of non-load-bearing systems (M6-M16, cracked and uncracked concrete)


E.g. threaded rods, metal structures, metal profiles, lattices, cable conduits, pipes, mounting rails etc.



For use in concrete < C20/25 and pressure-resistant natural stone (without approval)



May only be used in dry indoor conditions

Anchor diameter

10 mm

Anchor length (L H)

40 mm

Min./max. required screw-in depth

11-15 mm

Material

Steel

Surface

Zinc plated

Nominal drill-bit diameter (d 0)

12 mm

Drill hole depth (h 0)

40 mm

Effective anchoring depth (h ef)

40 mm

Torque during anchoring (T inst)

15 Nm

Through-hole in the component to be connected (d f)

12 mm

Approval

ETA-02/0044, ETA-05/0120

Minimum axis distance smin [mm] 70 - - 100 - - -
Effective anchorage depth hef [mm] 25 30 40 25 50 65 80
Nominal drill ∅ d0 [mm] 12 12 12 15 15 20 25
Drill cutting ∅ dcut ≤ [mm] 12,5 12,5 12,5 15,5 15,5 20,55 25,55
Drill hole depth h0 = [mm] 25 30 40 25 50 65 80
Through hole in the component being connected df ≤ [mm] 12 12 12 14 14 18 22
Thread depth (max. length of thread engagement) Lth [mm] 12 12 15 12 18 23 34
Minimum length of thread engagement Lsdmin ≤ [mm] 10 10 11 12 13 18 22
Torque while installing anchor Tinst ≤ [Nm] 15 15 15 35 35 60 120
Minimum edge distance cmin [mm] - 60 - 100 - -
Effective anchorage depth hef [mm] 25 25 30 25 30 40
Nominal drill ∅ d0 [mm] 8 8 8 10 10 10
Drill cutting ∅ dcut ≤ [mm] 8,45 8,45 8,45 10,45 10,45 10,45
Drill hole depth h0 = [mm] 25 25 30 25 30 40
Through hole in the component being connected df ≤ [mm] 6 7 7 9 9 9
Thread depth
(max. length of thread engagement)
Lth [mm] 10 12 13 12 13 20
Minimum length of thread engagement Lsdmin ≤ [mm] 6 6 7 8 9 9
Torque while installing anchor Tinst ≤ [Nm] 3 4 4 8 8 8
F120 [kN] - 0,3 0,3 0,6 -
F120 [kN] - 0,3 0,3 0,6 -
Thread depth
(max. length of thread engagement)
Lth [mm] 10 13 13 20 12 15 18 23 34
Minimum length of thread engagement Lsdmin ≤ [mm] 6 7 9 9 10 11 13 18 22
Torque while installing anchor Tinst ≤ [mm] 3 4 8 8 15 15 35 60 120
Fire resistance rating6) according to UTTC
(uniform temperature time curve)
F30 [kN] 4,7 6,9 12,5 18,0
F60 [kN] 2,4 3,5 5,6 8,5
F90 [kN] 1,3 1,8 3,5 5,5
F120 [kN] 1,0 1,4 2,5 4,4

Art.-no.
Cust. Mat. No.

Hazardous Material

Product information

Datasheets()

Datasheets ()

CAD data  | 

Certificates/ Documents

 | 

 | 

Technical information