Welcome to Würth India For trade customers only

W-FAZ PRO/A4 Stainless steel

ANC-(W-FAZ PRO/A4)-A4-0-40-M12X115

Art.-no. 5930412020

EAN 4062856404100

Individual price display after login
W-FAZ PRO/A4 Stainless steel

Art.-no. 5930412020

Individual price display after login
Quantity
PU
x 25 pcs

Exclusively for trade customers

Register now and access more than 125,000 products

High-performance stainless steel Fixanchor (CRC III) for cracked and uncracked concrete - for maximum load capacity and a reliable, long-lasting hold.
  • Highest loads at low spacing and edge distances: Large embedment depths enable a particularly high load capacity per anchor - even at reduced spacing and edge distances.

  • Quick installation, minimum effort: Extra-low embedment depths reduce drilling and embedment time and reduce the risk of reinforcement hits.

  • Economical and versatile: The freely selectable embedment depth enables optimum utilisation of the anchor - tailored to the application, load requirements and structural conditions.

  • Ideal for fastening close to edges: Minimal spacing and edge distances allow compact anchor plates as well as secure fastenings close to the concrete edge and in thin concrete members.

  • For applications subject to seismic activity: High performance under seismic activity - suitable for seismic performance categories C1 and C2.
Proof of Performance

European technical assessment ETA-20/0229 for single fixing point, option 1, cracked and uncracked concrete


  • Static or quasi-static loads.

  • Seismic activity, performance categories C1 and C2.

  • Fire resistance R30, R60, R90, R120.


Approved base materials


  • Cracked or uncracked concrete with a concrete compressive strength of C20/25 to C50/60 and C50/60 to C80/95.

  • Compressed, reinforced and non-reinforced normal weight concrete without fibres.

  • Steel fibre reinforced concrete (SFRC) with a concrete compressive strength of C20/25 to C50/60.


Load-bearing behaviour and fire exposure (standard time-temperature curve) - expert report no. GS 6.1/20-018-1


  • Fire duration 180 minutes (M8-M16).


Swiss Federal Office for Civil Protection (Bundesamt für Bevölkerungsschutz, BABS) - Approval for shock testing BZS D 20-602


  • Use in Swiss civil protection buildings (M8-M16, from standard anchorage depth hef,std).
Application area
Fastening of railings
Heavy steel structures
Post support bracket

Cable trays

Metal substructures

European technical assessment ETA-20/0229 for single fixing point, option 1, cracked and uncracked concrete


  • Static or quasi-static loads.

  • Seismic activity, performance categories C1 and C2.

  • Fire resistance R30, R60, R90, R120.


Approved base materials


  • Cracked or uncracked concrete with a concrete compressive strength of C20/25 to C50/60 and C50/60 to C80/95.

  • Compressed, reinforced and non-reinforced normal weight concrete without fibres.

  • Steel fibre reinforced concrete (SFRC) with a concrete compressive strength of C20/25 to C50/60.


Load-bearing behaviour and fire exposure (standard time-temperature curve) - expert report no. GS 6.1/20-018-1


  • Fire duration 180 minutes (M8-M16).


Swiss Federal Office for Civil Protection (Bundesamt für Bevölkerungsschutz, BABS) - Approval for shock testing BZS D 20-602


  • Use in Swiss civil protection buildings (M8-M16, from standard anchorage depth hef,std).
Product information

Datasheets(X)

Certificates/ Documents

 | 

 | 

Application area

For use as single fixing point or anchors in a redundant non-structural system with approval


  • In normal weight concrete C20/25 to C50/60 (cracked and uncracked concrete).

  • Suitable for pre-positioned installation, in-place installation and stand-off installation.


Suitable for anchoring medium to heavy loads in concrete:


Fastening of e.g. metal structures, supports, steel beams, brackets, railings, cable conduits, pipe conduits, wooden structures, beams, joist brackets etc.



Fastenings subject to seismic activity in earthquake-prone areas.



Fastenings subject to fire exposure.



W-FAZ PRO/A4 (A4 stainless steel) may be used in dry indoor areas and under all other conditions in accordance with EN 1993-1-4:2015-10 annex A, table A.3: CRC I-III.

Art.-no.
Cust. Mat. No.

Hazardous Material

Product information

Datasheets()

Datasheets ()

CAD data  | 

Certificates/ Documents

 | 

 | 

Technical information