  • ETA-02/0031 for individual attachment, option 1, cracked and non-cracked concrete, seismic performance category C1 and C2

  • Fire resistance: F30, F60, F90 and F120; exposure to fire according to DIN 1363-1:1999-10 (uniform temperature-time curve)

  • Fire resistance: R30, R60, R90 and R120; TR020 (included in ETA-02/0031)
Product information

Datasheets(X)

CAD data (available after login)

Certificates/ Documents

 | 

 | 

Metric anchor diameter

M16

Anchor length (l)

157 mm

Max. attachment height (t fix)

20 mm

Width across flats

24 mm

Nominal drill-bit diameter (d 0)

24 mm

Drill hole depth (h 1)

130 mm

Effective anchoring depth (h ef)

100 mm

Torque during anchoring (T inst)

160 Nm

Through-hole in the component to be connected (d f)

26 mm

Material

Steel

Surface

Zinc plated

Performance data
Anchor diameter [mm] M6 M8 M10 M12 M16 M16L M20
Admissible centric tension load1) on an individual anchor without the influence of the edge distance Tensile zone
(cracked concrete C20/252),
s ≥ 3 hef, c ≥ 1.5 hef)
Nadm [kN] = C20/252) 2,4 5,7 7,6 12,3 17,1 21,1 24,0
Compressive zone
(uncracked concrete C20/252))
minimum spacing and edge distances
(scr,sp ≥ 5 hef, ccr, sp ≥ 2.5 hef)
7,6 9,5 14,3 17,2 24,0 29,6 33,5
Admissible shear load1)
on an individual anchor
without the influence of the edge distance
Tensile zone
(cracked concrete C20/252),
c ≥ 10 hef)
W-HAZ-B/S/W-HAZ-S/S and W-HAZ-SK/S
Vadm [kN] = C20/252) 9.1/10.1 14.0/15.9 20.5/20.5 24.5/24.5 34.3/34.3 42.3/42.3 47.9/47.9
Compressive zone
(uncracked concrete C20/252), c ≥ 10 hef) W-HAZ-B/S/W-HAZ-S/S and W-HAZ-SK/S
9.1/10.1 14.0/17.1 20.7/27.5 34.3/34.3 48.0/48.0 52.1/59.2 67.1/67.1
Admissible bending moment Madm [Nm] 6,9 17,1 34,3 60 152 152 296,6
Admissible load when exposed to fire (R30, R60, R90, R120) see European Technical Approval ETA-02/0031
Fire resistance rating F30 [kN] 1,8 2,6 7,0 10,0 16,0 - -
Characteristic values
Minimum spacing smin ≥ [mm] 50 50 60 70 100 100 125
for c ≥ [mm] 50 80 120 140 180 180 300
Spacing scr, N [mm] 150 180 213 240 300 345 375
Minimum edge distance cmin ≥ [mm] 50 60 70 80 100 100 180
for s ≥ [mm] 100 120 175 200 220 220 540
Edge distance ccr, N [mm] 75 90 106,5 120 150 172,5 187,5
Minimum member thickness hmin [mm] 100 120 140 160 200 230 250
Effective anchorage depth hef [mm] 50 60 71 80 100 115 125