Welcome to Würth India For trade customers only

Fixanchor W-FAZ PRO/S

Fixanchor W-FAZ PRO steel zinc plated
ANC-(W-FAZ PRO/S)-(A2K)-0-50-M12X125

Art.-no. 5930212030
EAN 4062856404452

Prices for customers after login
Fixanchor W-FAZ PRO/S

Art.-no. 5930212030

Prices for customers after login
Quantity
PU
x 25 pcs

Exclusively for trade customers

Register now and access more than 125,000 products

High-performance wedge anchor for high loads in cracked and uncracked concrete, zinc-plated steel

Highest load values at low spacing and edge distances


Extra-large effective anchorage depths maximise the already high load values per anchor



Quick installation with fewer reinforcement hits


Extra-small effective anchorage depths minimise the drilling and embedment time



Economical and flexible application


Freely selectable embedment depth allows optimum utilisation of the anchors depending on the embedment depth and application



Minimal edge distances and spacing


Allows for fixings close to edges, small anchor plates and installation in thin concrete parts



For earthquake-proof construction


High performance under seismic action, seismic performance categories C1 and C2

Proof of Performance

European Technical Assessment ETA-20/0229 for individual fixing point, option 1, cracked and uncracked concrete:


  • Static or quasi-static action (M8-M16)

  • Seismic action, performance category C1 and C2 (M8-M16)

  • Fire resistance R30, R60, R90, R120


Load-bearing behaviour and fire resistance (uniform temperature curve) - expert report no. GS 6.1/20-018-1:


  • Fire duration 180 minutes (M8-M16)


Swiss Federal Office for Civil Protection (Bundesamt für Bevölkerungsschutz, BABS) - Approval for shock testing BZS D 20-602


  • Use in Swiss civil protection buildings (M8-M16, from standard anchorage depth hef,std)
Application area
Fastening of railings

Cable trays

Metal substructures
Heavy steel structures
Post support bracket

Create the drill hole

European Technical Assessment ETA-20/0229 for individual fixing point, option 1, cracked and uncracked concrete:


  • Static or quasi-static action (M8-M16)

  • Seismic action, performance category C1 and C2 (M8-M16)

  • Fire resistance R30, R60, R90, R120


Load-bearing behaviour and fire resistance (uniform temperature curve) - expert report no. GS 6.1/20-018-1:


  • Fire duration 180 minutes (M8-M16)


Swiss Federal Office for Civil Protection (Bundesamt für Bevölkerungsschutz, BABS) - Approval for shock testing BZS D 20-602


  • Use in Swiss civil protection buildings (M8-M16, from standard anchorage depth hef,std)
Product information

Datasheets(X)

Certificates/ Documents

 | 

 | 

Application area

Individual fixing point or anchors in a redundant non-structural system with approval


  • In normal weight concrete C20/25 to C50/60 (cracked and uncracked concrete)

  • Suitable for pre-positioned installation, in-place installation and stand-off installation


Suitable for anchoring medium to heavy loads in concrete:


Installation of e.g. metal constructions, supports, steel supports, brackets, railings, cable conduits, pipe sections, wooden constructions, beams, joist brackets etc.



Fastenings subject to seismic activity in earthquake-prone areas



Fastenings subject to exposure to fire



The W-FAZ PRO/S, galvanized steel, may only be used in dry indoor conditions

Metric anchor diameter

M12

Anchor length (l)

125 mm

Min./max. height of the fixture (t fix)

0-50 mm

Attachment height standard (t fix,std)

30 mm

Min. effective anchoring depth (h ef, min)

50 mm

Max. effective anchoring depth (h ef, max)

100 mm

Effective anchoring depth Standard (h ef, std)

70 mm

Usable length (B)

100 mm

Attachment height variable (t fix ,var)

B - hef

Disc diameter x disc thickness

24 x 2.5 mm

Width across flats

19 mm

Nominal drill-bit diameter (d 0)

12 mm

Drill hole depth variable (h 0, var)

hef + 10

Min. drill hole depth (h 0, min)

60 mm

Max. drill hole depth (h 0, max)

110 mm

Drill hole depth Standard (h 0, std)

80 mm

Material

Steel

Surface

Zinc plated

Torque during anchoring (T inst)

60 Nm

Through-hole in the component to be connected (d f)

14 mm

Thread type x anchor diameter x thread length (L th)

M12 x 70

Bolt protrusion (C)

16.0 mm

Approval

ETA-20/0229

Seismology C1

Yes

Seismology C2

Yes

Anchor diameter [mm] M8 M10 M12 M16
Variable effective anchorage depth hef,var [mm] The effective anchorage depth can be set to anywhere between hef,min and hef,max. The Würth Technical Software can help you with the calculation.
hef,min hef,max hef,std hef,min hef,max hef,std hef,min hef,max hef,std hef,min hef,max hef,std
352) 90 45 40 100 60 50 125 70 65 160 85
in cracked concrete
Admissible centric tension load in concrete C 20/253) Nadm [kN] 3,5 4,5 4,5 4,3 7,1 7,1 6,1 10,5 10,0 9,0 14,3 13,4
Admissible shear load in concrete C 20/253) Vadm [kN] 9,0 9,0 9,0 13,4 15,3 15,3 18,2 21,9 21,9 32,3 34,3 34,3
Admissible bending moment Madm [Nm] 17,1 34,3 60,0 137,1
in uncracked concrete
Admissible centric tension load in concrete C 20/253) Nadm [kN] 5,0 6,7 6,7 6,1 11,4 11,2 8,5 14,3 14,1 12,6 23,8 18,8
Admissible shear load in concrete C 20/253) Vadm [kN] 9,0 15,3 21,9 34,3
Admissible bending moment Madm [Nm] 17,1 34,3 60,0 137,1
Admissible load when exposed to fire (R30, R60, R90, R120), see European Technical Assessment ETA-20/0229
Admissible load when exposed to fire (F180) according to the uniform temperature curve based on TR20, see expert report no. GS 6.1/20-018-1
Nominal drill ∅ d0 [mm] 12 16
∅ of cutting edges dcut[mm] 12,5 16,5
Drill hole depth h0 [mm] hef+10 60 135 80 hef+14 79 174 99
Through hole in the fixture df[mm] 14 18
Width across flats AF [mm] 19 24
Torque while installing anchor Tinst = [mm] 60 110
Height of the hexagon nut tnut [mm] 10 13
Height x ∅ of washer tw x dw [mm] 2.5 x 24 3 x 30
Anchor diameter [mm] M8 M10
Variable effective anchorage depths hef hef,var hef,min hef,max hef,std hef,var hef,min hef,max hef,std
[mm] hef 35 90 45 hef 40 100 60
Embedment depth hnom [mm] hef+8 43 98 53 hef+9 49 109 69
Minimum member thicknesses hmin [mm] max
(1.5·hef; 80)
80 135 80 max
(1.5·hef; 80)
80 150 90
Minimum spacing smin [mm] 35 40
Minimum edge distance cmin [mm] 40 45
Nominal drill ∅ d0 [mm] 8 10
∅ of cutting edges dcut[mm] 8,45 10,45
Drill hole depth h0 [mm] hef+8 43 98 53 hef+9 49 109 69
Through hole in the fixture df[mm] 9 12
Width across flats AF [mm] 13 17
Torque while installing anchor Tinst = [Nm] 15 40
Height of the hexagon nut tnut [mm] 6,5 8
Height x ∅ of washer tw x dw [mm] 1.5 x 16 2 x 20

Art.-no.
Cust. Mat. No.

Hazardous Material

Product information

Datasheets()

Datasheets ()

CAD data  | 

Certificates/ Documents

 | 

 | 

Technical information